Theory Of Operation
When powered, the Occupant Restraint Controller (ORC) sends a test current to the squibs to verify the integrity of the squib and wiring. These circuits are maintained in a "floating" configuration at the ORC (connected to neither power nor ground) as protection against inadvertent deployment. Use of the Supplemental Restraints System (SRS) Load Tool Kit 8443A in the tests below substitutes a suspect squib with a known good component. The SRS Load Tool Adapter provides a test point as well as a method for opening the shorting bar connections within the ORC harness connector.